AUTOCLAVE
AUTOCLAVE DETAILS
A strong, pressurized, steam-heated vessel, for laboratory experiments sterilization. Each instrument or piece of medical equipment which comes into contact with a patient is a potential source of infection Minimize the risk of exposure to infection for each patient and provider. Sterilization by steam under pressure ensures complete elimination of all forms of microbial life.
STERILAB Series of Desktop, Vertical and Horizontal Steam Sterilizers both cylindrical and Rectangular are manufactured as per ASME design standards STERILAB Series Autoclaves offer user friendly operation.
Autoclaves are also known as steam sterilizers, and are typically used for healthcare or industrial applications. An autoclave is a machine that uses steam under pressure to kill harmful bacteria, viruses, fungi, and spores on items that are placed inside a pressure vessel. The items are heated to an appropriate sterilization temperature for a given amount of time.
The costs of an autoclave can vary greatly because of the various uses and applications of this technology. Industrial and pharmaceutical autoclaves are customized and manufactured for a specific use and therefore costs are likely to differ compared to autoclaves you find in a hospital or dental office.
In healthcare applications, the costs of an autoclave can range by capacity and installation method. Beyond the initial cost of the autoclave, the maintenance and cost of sterility assurance and monitoring products should be considered. Depending on the autoclave manufacturer, the costs per cycle, utility consumption and maintenance costs could vary over time and should be evaluated to compare your total-cost-of-ownership over time.
TYPE OF AUTOCLAVE
HORIZONTAL AUTOCLAVE
Triple wall with steam jacket
The autoclave is mounted on a Stainless steel tubular stand. The autoclave chamber & steam jacket are made of 10SWG SS 316. Stainless steel, outer shell which serves as a cover is made of stainless steel. Steam jacket allows dry sterilization. Hinged door is made of stainless steel. Radial locking arms prevent opening of the door while steam is inside the chamber. Autoclave is fitted with silicon gasket; steam is generated in a separate boiler which is placed below the main body. Multiport valve is provided for steam, dry sterilization & steam exhaust.
Autoclave is fitted with easily replaceable heaters and water level indicator. Autoclave holds pressure at selected point between 1 to 21 cg between 1 to 21cg +/- 3psi. Pressure control has markings which are approximate; the actual pressure is as shown by the pressure gauge. Hydraulically tested at 60psi.Fitted with safety valves pressure is as shown by the pressure gauge. Hydraulically tested at 40 psi. Fitted with safety valves, pressure gauges, steam release valve, steam top and one tray.
Single DOOR of size 120 liters capacity along with automatic temperature controller and printed output.
VERTICAL AUTOCLAVE
- Inner Wall : 450 mm dia X 650 mm depth (SS316)
- 2.Outer Wall : 550 mm dia X 900 mm depth (SS304)
- Power Supply : 6Kw / 230 VAC
- Temperature : 121°C and 15PSI
- LID Operation : Top lid with peddle lifting arrangement
- Control Panel : Fixed at the right side of the chamber
- Accessories : (i) Temperature Controller with timer
(ii) Pressure Switch
(iii) Water level Sensor
(iv) Drain Cock
(v) Safety Valve
8.Bin : 1 no. of standard bin
- Capacity : 110 Liter
Autoclave:
Cylindrical vessel, vertical type, double walled, with perferated bin,
Lid opened & closed by ring nuts. Door lifted by foot pedal. accessories
Relief valve, pressure switch, safety valve, pressure guage.
SI NO | Inner Dimension | Volume | |
1 | 250 x 450mm | 20 lit. | |
2 | 300 x 500 mm | 35 lit. | |
3 | 350 x 550 mm | 50lit. | |
4 | 400 x 600mm | 70lit. | |
5 | 450 x 600mm | 100lit. | |
6 | 550 x 750mm | 170lit. |
**Option for the above
Automatic Low level cutoff with float
Automatic Pressure cutoff
Digital timer
LABORATORY AUTOCLAVE
We are offering Laboratory Autoclave.
Attributes:
- Robust construction
- Easy operation
- High performance
Servo autoclaves (Vertical):
- This is double walled in construction
- Inner made up of SS & the outer made of thick mild steel sheet or SS
- The dish formed lid is made up of thick stainless steel plate
- An adjustable safety valve, pressure gauge, steam release cocks, are also provided
- Suitable for operation on 220/230 volts AC
Specifications:
S.No | Dimensions (Dia X Depth) |
Wattage |
1 | 350 X 550mm | 3KW |
2 | 400 X 550mm | 4KW |
3 | 450 X 600mm | 4KW |
4 | 550 X 750mm | 6KW |
Servo Autoclaves (Horizontal / Rectangular / Round):
S.No | Rectangular (B x D x H ) in mm |
Round (D X H) in mm |
Boiler Size (DxDepth) in mm |
Wattage |
1 | 400 x 400 x 600 | 400 x600 | 250 x450 | 6KW |
2 | 450 x 450 x 800 | 450 x800 | 300 x 500 | 9KW |
3 | 600 x 600 x 1200 | 600 x1200 | 350 x 600 | 12KW |
4 | 900 x 900 x 1500 | 900 x 1500 | 400 x 800 | 24KW |
PORTABLE AUTOCLAVE
Product Details:
- Lid pressed in dish form with thick stainless steel plate and suitable locking system
- An adjustable safety valve, pressure gauge and steam release cock provides adequate safety to the operator
- Available in round shape (vertical and horizontal) as per customer’s need
- Safety backup unit operates to cut off the power supply when chamber water is below the minimum level
Specifications:
- PLC with communication is optional
- 5 S Programmable PID digital temperature controller
- Outer wall made of stainless steel
SS STREAM STERILIZER
Product Details:
Brand | Pisces |
Voltage | 220 V |
Size | 450*450*1010 mm |
Frequency | 50 Hz |
Disinfecting Pressure | 0.22 MPa |
We are offering SS Steam Sterilizer.
Following are the salient attributes:
- High functionality
- Low maintenance
- Long working life
- Better efficiency
- Dimensional accuracy
ADVANTAGE
- Most metals, particularly stainless steel surgical instruments and lab utensils
- Polypropylene Pyrex® or Type I borosilicate glassware
- Biohazard waste
- Unwrapped goods
- It does not cause metals to corrode or rust
- It is relatively inexpensive
- It does not release any harmful or hazardous fumes or pollutants
Vacuum (pre and post) are appropriate for sterilizing large or porous items:
- Media solutions in appropriate containers, such as tissue culture flasks with loose caps for a steam autoclave cycle
- Pipette tips and other high-density polyethylene products, such as syringes
- Wrapped dry items that can trap air
- Animal cages and bedding